Airmar PB100 Technical Information Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
23
Connecting to a Generic NMEA 0183 Display
1. Route the WeatherStation cable to the display.
Do not
fasten the cable in place
at this time.
2. Connect the WeatherStation to the display.
Connector—If your WeatherStation came with a connector, and it can be
plugged into the port on your NMEA 0183 display, do so now. Coil any excess
cable and secure it with a zip-tie to prevent damage. Fasten the cable in place.
No connector—If your WeatherStation does not have a connector on the
display end, it
must
be hard wired. Follow “Guidelines for Making Connections”
to prepare the cable. Refer to the owner’s manual that came with your display
and connect the colored wires as shown in the table below and Figure 15.
Note 1: The WeatherStation must be supplied with 12 VDC+ at 0.5 amp
between the red and black leads.
Note 2: If your display does not have NMEA output connections, the yellow and
orange wires are not needed and their ends should be taped separately.
(Alternatively, yellow and orange wires can be connected to an external sensor.)
Note 3: The display power may be wired directly to the WeatherStation cable, or
it may be wired separately.
WeatherStation
Function
WeatherStation Cable Display Function
NMEA input A/+ Yellow NMEA output A/+ (see Note 2)
NMEA input B/– Orange NMEA output B/–
NMEA output A/+ White NMEA input A/+
NMEA output B/– Blue NMEA input B/–
12 VDC + Red (see Note 1) 12 VDC + (see Note 3)
12 VDC Black 12 VDC
Shield Bare Shield
Page view 22