Airmar PB100 Technical Information Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
20
Auxiliary NMEA OUT Grommets
Use the AUX NMEA OUT grommets to connect one or two additional devices to
receive and display data from the WeatherStation. To wire a device(s) through the
AUX NMEA OUT grommet(s), use the NMEA OUT terminals on the printed circuit
board (see Figure 13).
Note: If you will be connecting two devices, wire both devices to the same
designated terminals—on top of one another.
1. Route the cable coming from the additional display device(s) to the Combiner.
Do not
fasten the cable in place at this time.
2. Allowing an extra 25 cm (10") for wiring ease, cut the cable to length.
3. Remove the cover of the Combiner to expose the terminals inside.
4. Using a small Phillips screwdriver, puncture the grommet(s) that corresponds to
AUX NMEA OUT on the cover (see Figure 7).
Be careful
not to damage the
circuit board.
Figure 13. Wiring additional display devices to the Combiner
AIRMAR
WEATHER STATION
25-431-01
NMEA DISPLAY
ACTIVE RESEARCH L
TD 2005
C
SHIELD
A/+ B/- A/+ B/- - +
A/+
NMEA IN
NMEA OUT
PO
WER
NMEA
IN
SHIELD
NMEA IN
NMEA OUT
POWER
NMEA
IN
- +
B/-
B/-
A/+ B/- A/+
USB
050818-001 A
CTIS
SHIELD
PWR
GND
DM
DP
NMEA MULTIPLEXER
additional
display
additional
display
grommet
cable
Copyright © 2005 Airmar Technology Corp.
NMEA
display
cable
power
cable
PC